Title :
Thin and thick films of metal oxides and metal phthalocyanines as gamma radiation dosimeters
Author :
Arshak, Khalil ; Arshak, Arousian ; Zleetni, Saleh ; Korostynska, Olga
Author_Institution :
Electron. & Comput. Eng. Dept., Univ. of Limerick, Ireland
Volume :
51
Issue :
5
fYear :
2004
Firstpage :
2250
Lastpage :
2255
Abstract :
Numerous efforts were devoted to investigating the influence of radiation on metal oxides and polymer materials for dosimetry applications. Metal oxides, such as NiO, LaFeO3, CeO2, TeO2, In2O3, SiO and MnO, and polymers, such as CuPc, NiPc, MnPc and CoPc, were used as the active constituents in the fabrication of γ-radiation sensors. Thin and thick film devices were made in various topologies to form resistors, capacitors, pn-junctions and transistors. It was found that the properties of the active films (and, hence, their sensitivity to radiation) could be controlled by doping their constituent materials with carbon and mixing them in different proportions. The 60Co and 137Cs sources were used to expose the samples to γ-radiation. Current-voltage characteristics, optical absorption spectra, Raman spectra, SEM and XRD measurements were recorded for the samples after each exposure procedure and values of radiation damage were estimated. Thin film devices were found to be more sensitive to radiation than their thick film counterparts. Annealing was used to restore the properties of thick film devices after they were damaged with radiation. Thick films could be therefore reused on a repeatable basis, but thin film devices could not, as the heat treatments necessary for annealing were found to cause diffusion of the electrode materials. In this work, the possibility of fabricating a device that would satisfy the requirement of a particular application, such as sensitivity to γ-radiation and working dose region, was experimentally demonstrated. Based on the findings, these devices were found to provide a cost-effective alternative for room temperature real time γ-radiation dosimeter applications.
Keywords :
Raman spectra; X-ray diffraction; dosimeters; dosimetry; gamma-ray detection; gamma-ray effects; scanning electron microscopy; semiconductor counters; 137Cs sources; 60Co sources; CeO2; In2O3; LaFeO3; MOS; MnO; NiO; Raman spectra; SEM; SiO; TeO2; XRD; annealing; capacitors; carbon; current-voltage characteristics; device fabrication; diffusion; dosimetry applications; electrical properties; electrode materials; gamma radiation dosimeters; gamma-radiation sensors; metal oxide thick films; metal oxide thin films; optical absorption spectra; optical properties; personal dosimeter; phthalocyanines metal; pn-junctions; polymer materials; radiation damage; resistors; sensitivity; thick film devices; thin film devices; topologies; transistors; Annealing; Dosimetry; Fabrication; Gamma rays; Inorganic materials; Optical films; Polymers; Thick film devices; Thick films; Thin film devices; Gamma radiation; MOS; metal oxides; metal phthalocyanines; optical and electrical properties; personal dosimeter; pn-junction; thin and thick films;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2004.834718
Filename :
1344318
Link To Document :
بازگشت