DocumentCode
1140785
Title
Millimeter- and submillimeter-wave detection by paramagnetic materials
Author
Krumm, C.F. ; Haddad, G.I.
Author_Institution
Raytheon Research Division, Waltham, MA, USA
Volume
7
Issue
10
fYear
1971
fDate
10/1/1971 12:00:00 AM
Firstpage
475
Lastpage
484
Abstract
A scheme for detecting millimeter- and submillimeter-wave radiation by utilizing a paramagnetic material is described. An analysis of the scheme, which indicates the dependence of the noise-equivalent power on various parameters is given. Experimental results obtained at 35 and 50 GHz are presented. The scheme can be extended to higher frequencies by choosing the proper material and coupling structure.
Keywords
Absorption; Bandwidth; Energy states; Equations; Frequency conversion; Magnetic fields; Microwave devices; Paramagnetic materials; Radiation detectors; Tuning;
fLanguage
English
Journal_Title
Quantum Electronics, IEEE Journal of
Publisher
ieee
ISSN
0018-9197
Type
jour
DOI
10.1109/JQE.1971.1076561