DocumentCode
1141333
Title
Standing Wave Reduction in an RFI Laboratory
Author
Cory, W.E. ; Dolle, W.C. ; Milstead, F.C.
Author_Institution
Southwest Research Institute 8500 Culebra Road San Antonio, Texas
Volume
7
Issue
1
fYear
1965
fDate
3/1/1965 12:00:00 AM
Firstpage
64
Lastpage
72
Abstract
After review of some general properties of RF absorber materials, several of the standard and semistandard techniques for measuring absorber and anechoic chamber quality are discussed. A general purpose RFI laboratory is described together with a simple technique for evaluating the performance of absorber material as it is actually used. An effective background reflectivity of about 4% from 1 - 10 Gc was measured and is believed to be adequate for many applications.
Keywords
Anechoic chambers; Antenna measurements; Costs; Laboratories; Measurement standards; Radio frequency; Radiofrequency interference; Reflection; Reflectivity; Testing;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/TEMC.1965.4307381
Filename
4307381
Link To Document