• DocumentCode
    1141827
  • Title

    Functionally selective peripheral nerve stimulation with a flat interface nerve electrode

  • Author

    Tyler, Dustin J. ; Durand, Dominique M.

  • Author_Institution
    Dept. of Biomed. Eng., Case Western Reserve Univ., Cleveland, OH, USA
  • Volume
    10
  • Issue
    4
  • fYear
    2002
  • Firstpage
    294
  • Lastpage
    303
  • Abstract
    One of the important goals of peripheral nerve electrode development is to design an electrode for selective recruitment of the different functions of a common nerve trunk. A challenging task is gaining selective access to central axon populations. In this paper, a simple electrode that takes advantage of the neural plasticity to reshape the nerve is presented. The flat interface nerve electrode (FINE) reshapes the nerve into a flat geometry to increase the surface area and move central axon populations close to the surface. The electrode was implanted acutely on the sciatic nerve of eight cats. The FINE can significantly reshape the nerve and fascicles (p<0.0001) while maintaining the same total nerve cross-sectional area. The stimulation thresholds were 2.89 nC for pulse amplitude modulation and 10.2 nC for pulsewidth modulation. Monopolar, square-pulse stimulation with single contacts on the FINE selectively recruited each of the four main branches of the sciatic nerve. Simultaneous stimulation with two contacts produced moments about the ankle joint that were a combination of the moments produced by the individual contacts when stimulated separately.
  • Keywords
    bioelectric phenomena; biomedical electrodes; neuromuscular stimulation; acutely implanted electrode; ankle joint; cats; central axon populations; flat interface nerve electrode; functionally selective peripheral nerve stimulation; individual contacts; monopolar square-pulse stimulation; nerve reshaping; neural plasticity; pulsewidth modulation; sciatic nerve main branches; selective recruitment; simple electrode; stimulation thresholds; Amplitude modulation; Contacts; Electrodes; Engine cylinders; Nerve fibers; Pulse modulation; Recruitment; Safety; Shape; Spirals; Anatomy, Cross-Sectional; Animals; Ankle Joint; Cats; Electric Stimulation; Electric Stimulation Therapy; Electrodes, Implanted; Equipment Design; Equipment Failure Analysis; Muscle, Skeletal; Peripheral Nerves; Recruitment, Neurophysiological; Reproducibility of Results; Sciatic Nerve; Sensitivity and Specificity;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2002.806840
  • Filename
    1178100