Title :
Prototype IVA module
Author :
Thomas, Ken J. ; Williamson, Mark C. ; Clough, Stephen G. ; Phillips, Martin J.
Author_Institution :
Pulsed Power Group, AWE, Reading, UK
fDate :
10/1/2002 12:00:00 AM
Abstract :
A prospective module has been designed for a future large inductive voltage adder (IVA) machine that would be suitable for the most demanding radiography carried out at AWE Aldermaston, Berkshire, UK. This machine would operate at 13-15 MV. The prototype IVA module (PIM) machine has been built to test a single such module and may also provide the basis for other, lower voltage machines in the future. It consists of a single inductive cavity pulsed by a 10-Ω water dielectric Blumlein pulse forming line which is charged by a Marx generator. The Blumlein switch initially installed was a coaxial two stage Rimfire and Trigatron switch. A laser triggering configuration utilizing two radial switches, designed by Titan PSI, is also to be tested. The Blumlein PFL and its switch were tested using a copper sulphate resistive load and achieved a peak output voltage of 1.7 MV. The inductive cavity has been added and a pulse of 1.5-MV peak voltage has been successfully applied to it.
Keywords :
gas-discharge tubes; laser beam applications; power transmission lines; pulsed power supplies; pulsed power switches; radiography; 1.5 MV; 1.7 MV; 10 ohm; 13 to 15 MV; AWE Aldermaston; Marx generator; Metg1as; Titan PSI; UK; coaxial two stage Rimfire and trigatron switch; copper sulphate resistive load; inductive cavity; inductive voltage adder; laser triggering configuration; peak output voltage; radial switches; radiography; single inductive cavity; water dielectric Blumlein pulse forming line; Coaxial components; Copper; Dielectrics; Optical design; Optical pulse generation; Prototypes; Radiography; Switches; Testing; Voltage;
Journal_Title :
Plasma Science, IEEE Transactions on
DOI :
10.1109/TPS.2002.806642