Abstract
The Institute for Advanced Technology (IAT) has tested a high-inductance-gradient series-connected two-turn railgun. The primary goal of these experiments was to launch a dual-armature launch package in the two-turn configuration while maintaining electrical isolation between the rail and armature pairs. Two tests with the dual-armature launch package on a single-turn configuration independently examined the performance of the launch package. Results of those tests showed good thermal and structural performance of the armature assembly and no melt transfer between the armature contact regions. Five tests were then conducted on the two-turn rail configuration. During the second test, the crossover that connects the two rail pairs at the breech suffered arcing damage at the rail contacts. A new crossover was fabricated, and all subsequent tests were successful with no crossover arcing. The final system had a propulsive inductance gradient of 1.8 mu H/m, with projectiles successfully launched in excess of 400 m/s at linear current densities up to 35 kA/mm.
Keywords
projectiles; railguns; rails; Institute for Advanced Technology; dual-armature launch package; electrical isolation; high-inductance-gradient two-turn railgun; linear current densities; propulsive inductance gradient; rail contacts; series-connected two-turn railgun; size 40 mm; Crossover; dual armature; multi-turn; railgun;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.2008.2008872
Filename
4773637
Link To Document