• DocumentCode
    1144409
  • Title

    Extended life of telecom relays by using SF6

  • Author

    Johler, Werner

  • Author_Institution
    Tyco Electron., AXICOM Ltd., Au, Switzerland
  • Volume
    25
  • Issue
    4
  • fYear
    2002
  • fDate
    12/1/2002 12:00:00 AM
  • Firstpage
    663
  • Lastpage
    669
  • Abstract
    The excellent dielectric characteristics of Sulfur-Hexafluoride (SF6) are well known and have been applied for many years in high and medium voltage equipment and even in very small switches like telecom relays. The use of SF6 in telecom relays increased the dielectric performance of relays although the dimensions were significantly reduced at the same time. Beside the improved dielectric performance, the electrical life and switching capability of the relays were significantly extended. On practically all tested loads at least the same, on many loads an extension of the electrical life could be found, e.g., maximum load, ringing load and others. Also the allowed switching range could be increased by a factor of two as the material transfer and erosion characteristics were improved significantly.
  • Keywords
    SF6 insulation; contact resistance; electronic equipment testing; life testing; relays; telecommunication equipment; telecommunication switching; Auger analysis; SEM analysis; SF6; SF6 gas; contact erosion; dielectric performance; electrical endurance tests; electrical life extension; electromechanical relays; erosion characteristics improvement; material transfer characteristics improvement; switching capability; telecom relays; Contact resistance; Dielectric breakdown; Electrons; Medium voltage; Packaging; Relays; Switches; Switching circuits; System testing; Telecommunication switching;
  • fLanguage
    English
  • Journal_Title
    Components and Packaging Technologies, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1521-3331
  • Type

    jour

  • DOI
    10.1109/TCAPT.2003.809107
  • Filename
    1178773