DocumentCode :
1144763
Title :
Parametric oscillator tuning curve from observations of total parametric fluorescence
Author :
Pearson, J.E. ; Ganiel, U. ; Yariv, A.
Author_Institution :
California Institute of Technology, Pesadena, CA, USA
Volume :
8
Issue :
3
fYear :
1972
fDate :
3/1/1972 12:00:00 AM
Firstpage :
383
Lastpage :
385
Abstract :
Measurements of total emitted parametric fluorescence power are presented and used to fix one point on the predicted tuning curve of a parametric oscillator. The method is particularly useful for predicting the tuning curve of infrared pumped parametric oscillators. Experimental results, which verify the usefulness of the technique in a 1.06-μ-pumped oscillator, are presented.
Keywords :
Bandwidth; Fluorescence; Frequency; Nonlinear optics; Optical pumping; Optical sensors; Optical tuning; Oscillators; Power measurement; Wavelength measurement;
fLanguage :
English
Journal_Title :
Quantum Electronics, IEEE Journal of
Publisher :
ieee
ISSN :
0018-9197
Type :
jour
DOI :
10.1109/JQE.1972.1076959
Filename :
1076959
Link To Document :