    The improvement of dynamic characteristics of ultrasonic therapeutic transducers using fine-grain PZT-based piezoceramics

  • Author

    Tsai, Cheng-Che ; Chiang, Te-Kuang ; Chu, Sheng-Yuan

  • Author_Institution
    Dept. of Electron. Eng., Southern Taiwan Univ., Tainan
  • Volume
    56
  • Issue
    1
  • fYear
    2009
  • fDate
    1/1/2009 12:00:00 AM
  • Firstpage
    156
  • Lastpage
    166
  • Abstract
    Optimizing the dynamic resonant characteristics of ultrasonic therapeutic transducers depends most importantly on fine-grain piezoceramics with good resonant properties. In this paper, we prepare and compare modified Pb/.99Sr0.01[0.03(Mn1/3Nb2/3)-0.97(Zr0.51Ti0.49)]O3 piezoceramics with 0.1 wt% CaCO3 and 0.8 wt% PbO additives (PMZT3) synthesized by B-oxides precursor (BO) and conventional ceramic mixed-oxide methods (MO). Our experimental results show that the BO-type piezoceramics have better grain microstructure and better material properties [e.g., d33= 340 pc/N, kt= 0.52, Qm= 1250, temperature coefficient of change rate of resonant frequency (TCF) = 0.01%/degC, and temperature coefficient of change rate of clamped capacitance (TCC) = 0.18%/degC]. We construct 1-MHz transducers using our BO and MO types of piezoceramics and examine their dynamic resonant characteristics as the transducers are driven by a power driver with open-loop control. Results show that the transducers with the BO-type piezoceramics have better dynamic characteristics, such as time stability (e.g., aging rate of resonant frequency at thickness mode = 0.26%/decade cycle, and aging rate of clamped capacitance = 0.55%/decade cycle) and temperature stability as BO-type piezoceramics. Furthermore, we observe that the clamped capacitance variation has more influence on the transducer dynamic characteristics than the resonant frequency variation, and we verify the observation from the partial derivative ratio of the transfer function derived by a simulated ultrasonic equivalent circuit system. It is concluded that the BO-type piezoceramics are better candidates than the MO-type samples for obtaining optimum dynamic resonant characteristics in ultrasonic therapeutic transducers.
  • Keywords
    biomedical ultrasonics; lead compounds; patient treatment; piezoceramics; ultrasonic transducers; B-oxides precursor; PMZT3 additives; PZT-CaCO3-PbO; Pb0.99Sr0.01[(Mn0.33Nb0.67)-(Zr0.51Ti0.49)]O3; ceramic mixed-oxide methods; clamped capacitance; dynamic resonant characteristics; fine-grain PZT-based piezoceramics; grain microstructure; resonant frequency; ultrasonic equivalent circuit system; ultrasonic therapeutic transducers; Additives; Aging; Capacitance; Niobium; Piezoelectric materials; Resonance; Resonant frequency; Strontium; Temperature; Ultrasonic transducers; Ceramics; Equipment Design; Temperature; Transducers; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2009.1015
  • Filename
    4775274