• DocumentCode
    1146146
  • Title

    Syllectometry: the effect of aggregometer geometry in the assessment of red blood cell shape recovery and aggregation

  • Author

    Dobbe, Johannes G G ; Streekstra, Geert J. ; Strackee, Jan ; Rutten, Marcel C M ; Stijnen, Johannes M A ; Grimbergen, Cornelis A.

  • Author_Institution
    Acad. Med. Center, Amsterdam Univ., Netherlands
  • Volume
    50
  • Issue
    1
  • fYear
    2003
  • Firstpage
    97
  • Lastpage
    106
  • Abstract
    Syllectometry is a measuring method that is commonly used to assess red blood cell (RBC) aggregability. In syllectometry, light is incident on a layer of whole blood initially exposed to shear flow. The backscattered light is measured after abruptly stopping the driving mechanism. The resultant time-dependent intensity plot is called the syllectogram. Parameters that quantify RBC aggregability are obtained by analyzing the syllectogram. As we will show in this paper, the upstroke in the initial part of the syllectogram contains the information for measurement of RBC-shape recovery in whole blood as well. To estimate RBC-shape recovery, we extended the existing two-exponential mathematical representation of the syllectogram by a third exponent that describes the upstroke. To investigate the feasibility of RBC-shape recovery measurement from the upstroke, we derived an analytical model of the flow decay that follows after abruptly stopping the driving mechanism. The model reveals that for large gaps the flow decay may interfere with the true RBC-shape recovery process. These theoretical findings were confirmed by velocity measurements in a Couette-type aggregometer. Syllectograms obtained using large gaps differ in many respects from those obtained using small gaps. As predicted by our model large gaps show a prolonged apparent shape-recovery time-constant. Moreover, a delayed intensity peak, a reduced upstroke of the intensity peak and a considerable increase of the half-life parameter are observed. The aggregation indices for large gaps are lower than for small gaps. This paper yields a better understanding of the velocity and shear-rate decay following upon abruptly stopping the driving mechanism. A better mathematical representation of the syllectogram and recommendations for a maximum gap width enables both RBC-shape recovery and aggregation measurements in whole blood using syllectometry.
  • Keywords
    aggregation; backscatter; cellular transport; haemorheology; light scattering; physiological models; Couette-type aggregometer; aggregometer geometry effect; analytical model; backscattered light; delayed intensity peak; erythrocytes; intensity peak; mathematical representation; maximum gap width; red blood cell shape recovery assessment; shear flow; syllectometry; upstroke; Analytical models; Biomedical engineering; Biomedical measurements; Diseases; Fluid flow measurement; Geometry; Physics; Red blood cells; Shape measurement; Velocity measurement; Blood Flow Velocity; Blood Viscosity; Elasticity; Equipment Failure Analysis; Erythrocyte Aggregation; Erythrocyte Deformability; Erythrocytes; Hemorheology; Humans; Laser-Doppler Flowmetry; Models, Cardiovascular; Nephelometry and Turbidimetry; Quality Control; Reproducibility of Results; Scattering, Radiation; Sensitivity and Specificity; Shear Strength; Stress, Mechanical;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2002.807319
  • Filename
    1179136