DocumentCode :
1146985
Title :
Simulator Study of Multiterminal HVDC Transmission System without Fast Communication
Author :
Ishikawa, M. ; Horiuchi, S. ; Irokawa, S. ; Imai, K. ; Hirose, S. ; Sekiya, K.
Author_Institution :
Tokyo Electric Power Company, Tokyo, Japan
Volume :
1
Issue :
3
fYear :
1986
fDate :
7/1/1986 12:00:00 AM
Firstpage :
218
Lastpage :
227
Abstract :
AC/DC simulator studies for a 4-terminal HVDC system have been carried out to demonstrate the operating performance of the multiterminal HVDC control scheme, "the 2-ACR method", which does not require fast communication systems. A microcomputer is used for converter control. Satisfactory operations have been confirmed through various types of simulations. Examples of an effective and economical DC circuit breaker application, for an AC system fault at the inverter and a DC line fault, are described.
Keywords :
Circuit breakers; Circuit faults; Circuit simulation; Communication system control; Control systems; HVDC transmission; Inverters; Power generation economics; Rectifiers; Voltage control;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/TPWRD.1986.4307996