DocumentCode
1148425
Title
Species composition in a CO2 laser discharge
Author
Tannen, P. ; Bletzinger, P. ; Garscadden, A.
Author_Institution
Wright-Patterson Air Force Base, OH
Volume
9
Issue
1
fYear
1973
fDate
1/1/1973 12:00:00 AM
Firstpage
192
Lastpage
193
Abstract
Recent experimental studies have shown that small quantities of nitrogen oxides can seriously effect discharge stability and power output in flowing CO2 discharge lasers. In the present study, the formation of these oxides was measured in a sealed-off discharge tube under operating conditions similar to those in CO2 lasers. The gas composition was sampled with a modulated molecular beam, low-voltage ionizer, quadrupole mass spectrometer. The combined use of low ionizer voltage and phase sensitive detection eliminated extraneous mass peaks caused by background gases and dissociative ionization in the analyzer itself. Equilibrium and time-varying measurements were made of neutral and ionix species. Two initial gas compositions were used 1) 71.8 percent He, 15.5 percent N2 , 12.7 percent CO2 , and 2) 87.2 percent He, 12.8 percent CO2 . Measurements were made in a discharge tube 2.2 cm inside diameter, 26 cm between electrodes. The system was pumped to approximately 10-6mm Hg between data runs. Total pressure was varied from 1 to 8 mm Hg and discharge current from 0 to 80 mA. Typical CO2 dissociation data at 40 mA and 4 mm Hg indicate an initial rate of
s-1with an equilibrium value of approximately 65 percent dissociation in the He/ N2 /CO2 mixture and slightly lower vatues in the He/CO2 mixture. Under the same conditions, nitric oxide (NO) exhibited a buildup rate of
s-1with an equilibrium value of approximately 0.1 percent of total gas composition. Nitrogen diozide (NO2 ) was detected by comparing the relative amounts of mass numbers 45 and 46. Data indicate that in the He/N2 / CO2 mixture the NO2 component of mass 46 can be as high as 0.12 percent of total mixture with an initial buildup rate of
s-1- t 80 mA discharge current. Measurement of the ion spectra at the cathode indicate that CO2 + is the major initial ion in the He/N2 /CO2 mixture, but decays with a rate of
s-1and is replaced by NO+at approximately the same rate. In the He/CO2 mixture CO2 + is replaced as the major ion by O2 + , with with slightly lower rates than those measured in the mixtures containing N2 .
s-1with an equilibrium value of approximately 65 percent dissociation in the He/ N
s-1with an equilibrium value of approximately 0.1 percent of total gas composition. Nitrogen diozide (NO
s-1- t 80 mA discharge current. Measurement of the ion spectra at the cathode indicate that CO
s-1and is replaced by NO+at approximately the same rate. In the He/COKeywords
Electron tubes; Gas lasers; Laser stability; Low voltage; Mass spectroscopy; Mercury (metals); Nitrogen; Optical modulation; Power lasers;
fLanguage
English
Journal_Title
Quantum Electronics, IEEE Journal of
Publisher
ieee
ISSN
0018-9197
Type
jour
DOI
10.1109/JQE.1973.1077322
Filename
1077322
Link To Document