• DocumentCode
    1148673
  • Title

    Impulse Breakdown Characteristics of Coated Electrodes in SF6 Gas

  • Author

    Honda, M. ; Okubo, H. ; Aoyagi, H. ; Inui, A.

  • Author_Institution
    Toshiba Corporation Kawasaki, Japan
  • Volume
    2
  • Issue
    3
  • fYear
    1987
  • fDate
    7/1/1987 12:00:00 AM
  • Firstpage
    699
  • Lastpage
    708
  • Abstract
    The authors investigated the impulse breakdown characteristics of coated high-voltage electrodes in SF6 gas with a varying nonuniform factor, electrode area, and coating material. From the viewpoint of the relation between breakdown stress and the stressed electrode area, it was clarified that with coated electrodes, breakdown voltage remains, with an increasing electrode area, nearly at the theoretically estimated level for SF6 gas breakdown without showing any decrease due to the area effect (in contrast to bare electrodes). Moreover, it was also recognized that repeated breakdown characteristics of coated electrodes differed depending on the coating materials.
  • Keywords
    Breakdown voltage; Coatings; Electric breakdown; Electrodes; Estimation theory; Gas insulation; Rough surfaces; Sulfur hexafluoride; Surface roughness; Testing;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.1987.4308166
  • Filename
    4308166