DocumentCode
1148705
Title
Effect of electrode ice layer on prebreakdown current in liquid nitrogen
Author
Hanaoka, R. ; Ishibashi, R. ; Usui, Y. ; Inagaki, D.
Author_Institution
Dept. of Electr. Eng., Kanazawa Inst. of Technol., Ishikawa, Japan
Volume
1
Issue
4
fYear
1994
fDate
8/1/1994 12:00:00 AM
Firstpage
741
Lastpage
746
Abstract
The effect of ice on dc prebreakdown events was investigated using a needle-to-plane electrode system in liquid nitrogen at 77.3 K. It was found that H2O ice has marked effects on prebreakdown current, corona onset voltage and breakdown voltage. The breakdown voltage at atmospheric pressure depends on microscopic cracks in H2 O ice
Keywords
corona; cryogenics; electric breakdown of liquids; electrodes; ice; nitrogen; 77.3 K; N2; atmospheric pressure; breakdown voltage; corona onset voltage; dc prebreakdown events; electrode ice layer; liquid nitrogen; microscopic cracks; needle-to-plane electrode system; prebreakdown current; Breakdown voltage; Conductivity; Corona; Electrodes; Fiber reinforced plastics; Ice; Microscopy; Needles; Nitrogen; Temperature;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/94.311719