DocumentCode
1150366
Title
γ-ray irradiation durability of erbium-doped fibres
Author
Fukuda, C. ; Chigusa, Y. ; Kashiwada, T. ; Onishi, M. ; Kanamori, H. ; Okamoto, Shusuke
Author_Institution
Sumitomo Electr. Ind. Ltd., Yokohama
Volume
30
Issue
16
fYear
1994
fDate
8/4/1994 12:00:00 AM
Firstpage
1342
Lastpage
1344
Abstract
The long-term behaviour of erbium-doped fibres under γ-ray irradiation at a low dose rate of 0.5R/year was predicted for the purpose of applying the fibres to transoceanic transmission systems, based on the experimental result that permanent defects in fibres were dominantly generated at low dose rates. The estimated degradation of transmission loss and amplification gain after 25 years in undersea were 0.04 dB/km and 0.3 dB, respectively
Keywords
erbium; gamma-ray effects; optical cables; optical fibres; optical losses; γ-ray irradiation durability; Er3+-doped fibre; amplification gain; dose rates; low dose rate; permanent defects; transmission loss; transoceanic transmission systems;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19940870