DocumentCode
1154256
Title
Improved PDP sustainers for reducing current stress and nonlinear effect
Author
Wu, Tsai-Fu ; Chen, Chien-Chih ; Chiu, Shao-Wei
Author_Institution
Dept. of Electr. Eng., Nat. Chung Cheng Univ., Chia-Yi, Taiwan
Volume
19
Issue
6
fYear
2004
Firstpage
1380
Lastpage
1387
Abstract
This work presents three improved plasma display panel (PDP) sustainers for reducing current stress and nonlinear effect due to parasitic and distributed components. In the paper, a useful cell equivalent circuit model is first introduced to describe the behavior of PDP cell operation, and a widely used sustainer is then reviewed, on which three improved ones are proposed. The proposed sustainers can reduce currents through the switches and nonlinear effect due to parasitic and distributed components along the energy-recovery circuit paths. Derivation and operating principle of the proposed sustainers are addressed in detail. In addition, their related gaseous discharge mechanism in PDP cells is also presented. Hardware measurements have verified the feasibility of the proposed sustainers.
Keywords
equivalent circuits; plasma displays; cell equivalent circuit model; current stress reduction; energy-recovery circuit path; gaseous discharge mechanism; nonlinear effect reduction; plasma display panel sustainer; Capacitance; Equivalent circuits; Flat panel displays; Inductors; Plasma displays; Plasma measurements; Stress; Switches; Switching circuits; System performance; 65; PDP; Plasma display panel; sustainers;
fLanguage
English
Journal_Title
Power Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0885-8993
Type
jour
DOI
10.1109/TPEL.2004.836637
Filename
1353328