DocumentCode :
1156743
Title :
Design and Development of a New Multi-Projection X-Ray System for Chest Imaging
Author :
Chawla, Amarpreet S. ; Boyce, Sarah ; Washington, Lacey ; McAdams, H. Page ; Samei, Ehsan
Author_Institution :
Dept. of Radiol., Duke Univ., Durham, NC
Volume :
56
Issue :
1
fYear :
2009
Firstpage :
36
Lastpage :
45
Abstract :
Overlapping anatomical structures may confound the detection of abnormal pathology, including lung nodules, in conventional single-projection chest radiography. To minimize this fundamental limiting factor, a dedicated digital multi-projection system for chest imaging was recently developed at the Radiology Department of Duke University. We are reporting the design of the multi-projection imaging system and its initial performance in an ongoing clinical trial. The system is capable of acquiring multiple full-field projections of the same patient along both the horizontal and vertical axes at variable speeds and acquisition frame rates. These images acquired in rapid succession from slightly different angles about the posterior-anterior (PA) orientation can be correlated to minimize the influence of overlying anatomy. The developed system has been tested for repeatability and motion blur artifacts to investigate its robustness for clinical trials. Excellent geometrical consistency was found in the tube motion, with positional errors for clinical settings within 1%. The effect of tube-motion on the image quality measured in terms of impact on the modulation transfer function (MTF) was found to be minimal. The system was deemed clinic-ready and a clinical trial was subsequently launched. The flexibility of image acquisition built into the system provides a unique opportunity to easily modify it for different clinical applications, including tomosynthesis, correlation imaging (CI), and stereoscopic imaging.
Keywords :
cancer; computerised tomography; diagnostic radiography; lung; chest imaging; correlation imaging; image acquisition; lung nodules; modulation transfer function; multiprojection X-ray system; posterior-anterior orientation; single-projection chest radiography; stereoscopic imaging; tomosynthesis; Anatomical structure; Anatomy; Clinical trials; Lungs; Optical imaging; Pathology; Radiography; Radiology; System testing; X-ray imaging; Chest radiography; correlation imaging; lung cancer; stereoscopy; tomosynthesis;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2008.2008647
Filename :
4782127
Link To Document :
بازگشت