DocumentCode
11596
Title
Improved Evaluation of Dynamic Mechanical Properties of Soft Materials With Applications to Minimally Invasive Surgery
Author
Araghi, M.H. ; Salisbury, Shaun P.
Author_Institution
Dept. of Electr. & Comput. Eng., Univ. of Western Ontario, London, ON, Canada
Volume
18
Issue
3
fYear
2013
fDate
Jun-13
Firstpage
973
Lastpage
980
Abstract
Minimally invasive surgery minimizes trauma to the patient, however, the loss of tactile feedback impedes the surgeon´s ability to locate tumors among healthy tissue. In this paper, a resonance-based instrument to measure the stiffness, damping, and effective mass of a soft material such as biological tissue is presented. It was designed to be small yet has two natural frequencies below 100 Hz so that the effective mass of the tissue would not impact the determination of the stiffness. A state-space model was used to develop a fast and accurate method of extracting the tissue parameters by measuring the natural frequencies and the bandwidth at the first natural frequency. A fast and robust phased-locked-loop-based feedback system is described, which was used to measure the required frequencies. Simulations showed that the system was robust, while subjected to disturbances including hand tremor, tissue parameter variation, and preload. A prototype system showed that the instrument could accurately predict the stiffness, damping, and mass with an average error of 6%, 6%, and 7%, respectively. Experiments on a simulated tissue phantom showed the ability of the instrument to detect a tumour while it was stationary and in motion.
Keywords
biomechanics; biomedical equipment; biomedical measurement; damping; elastic constants; frequency measurement; injuries; mass measurement; phantoms; state-space methods; surgery; tumours; biological tissue; damping measurement; dynamic mechanical properties; effective mass measurement; frequency measurement; hand tremor; minimally invasive surgery; prototype system; resonance-based instrument; robust phased-locked-loop-based feedback system; simulated tissue phantom; soft materials; state-space model; stiffness measurement; tactile feedback; tissue parameter variation; trauma; tumour; Damping; Frequency measurement; Instruments; Materials; Phase locked loops; Resonant frequency; Surgery; Mechanical impedance; minimally invasive surgery (MIS); natural frequency shift; phase-locked loop (PLL); soft tissue mechanical properties;
fLanguage
English
Journal_Title
Mechatronics, IEEE/ASME Transactions on
Publisher
ieee
ISSN
1083-4435
Type
jour
DOI
10.1109/TMECH.2012.2195324
Filename
6196227
Link To Document