• DocumentCode
    1160374
  • Title

    Thermometry of lossy microstriplines by correlation radiometry

  • Author

    Waro, P. ; Leroy, Y.

  • Author_Institution
    Inst. d´´Electron. et de Microelectron. du Nord, UMR-CNRS, Villeneuve d´´Ascq, France
  • Volume
    141
  • Issue
    4
  • fYear
    1994
  • fDate
    8/1/1994 12:00:00 AM
  • Firstpage
    307
  • Lastpage
    312
  • Abstract
    The notion of correlation temperature resulting from the thermal noise of a passive symmetrical lossy two-port is applied to microwave microstriplines made lossy by implantation of small-size resistors. The case of an isothermal line is considered, followed by the case of a hot spot created on the line in which it is possible to emphasise its contribution in terms of correlation temperature. The study is illustrated by extensive experimental verifications in the bandwidth of 2-4 GHz. A method of inversion is presented based on Kalman filtering of the radiometric data, and leading to thermal profiling along the microstriplines
  • Keywords
    Kalman filters; correlation methods; filtering and prediction theory; microstrip lines; microwave measurement; radiometers; radiometry; temperature measurement; thermal noise; 2 to 4 GHz; Kalman filtering; SHF; UHF; correlation radiometry; correlation temperature; hot spot; inversion; isothermal line; lossy microstriplines; microwave microstriplines; passive symmetrical lossy two-port; small-size resistors; thermal noise; thermal profiling;
  • fLanguage
    English
  • Journal_Title
    Microwaves, Antennas and Propagation, IEE Proceedings
  • Publisher
    iet
  • ISSN
    1350-2417
  • Type

    jour

  • DOI
    10.1049/ip-map:19941240
  • Filename
    313246