DocumentCode
1161702
Title
Performance of a Circuit for Display of Pulses Associated with Gap Discharges
Author
Dobroszewski, R. ; Janischewskyj, W.
Author_Institution
Technical University of Poznan
Issue
5
fYear
1981
fDate
5/1/1981 12:00:00 AM
Firstpage
2695
Lastpage
2702
Abstract
Meaningful determination of electrical characteristics for discharges occuring in short gaps have been made possible through the use of a special circuit adopted for display of subnanosecond pulses with relatively high amplitudes. The measuring system developed by the authors includes a point-to-point electrode geometry of very low capacitance, a special high voltage probe serving as a high peak power 50 Q attenuator, a coaxial cable and a wide-band oscilloscope.
Keywords
Attenuation measurement; Capacitance measurement; Displays; Electric variables; Electrodes; Geometry; Power measurement; Pulse circuits; Q measurement; Voltage;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1981.316748
Filename
4110922
Link To Document