DocumentCode :
1161702
Title :
Performance of a Circuit for Display of Pulses Associated with Gap Discharges
Author :
Dobroszewski, R. ; Janischewskyj, W.
Author_Institution :
Technical University of Poznan
Issue :
5
fYear :
1981
fDate :
5/1/1981 12:00:00 AM
Firstpage :
2695
Lastpage :
2702
Abstract :
Meaningful determination of electrical characteristics for discharges occuring in short gaps have been made possible through the use of a special circuit adopted for display of subnanosecond pulses with relatively high amplitudes. The measuring system developed by the authors includes a point-to-point electrode geometry of very low capacitance, a special high voltage probe serving as a high peak power 50 Q attenuator, a coaxial cable and a wide-band oscilloscope.
Keywords :
Attenuation measurement; Capacitance measurement; Displays; Electric variables; Electrodes; Geometry; Power measurement; Pulse circuits; Q measurement; Voltage;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1981.316748
Filename :
4110922
Link To Document :
بازگشت