• DocumentCode
    1163711
  • Title

    Sequential cardiac segmentation by seed contour tracking

  • Author

    Cho, J.

  • Author_Institution
    Samsung Electron. Co., Suwon, South Korea
  • Volume
    40
  • Issue
    23
  • fYear
    2004
  • Firstpage
    1467
  • Lastpage
    1469
  • Abstract
    A sequential cardiac segmentation method based on an active contour model, initial seed contour tracking (SCT) scheme, and phase contrast magnetic resonance imaging (MRI) has been developed to improve the accuracy of automatic sequential segmentation of the myocardial boundaries, especially the endocardial boundary. The performance of the proposed method was assessed by experiments performed on phase contrast MRI data sets from three normal human volunteers. Experimental results showed that the propagation of errors caused by improper positioning of initial seed contours in sequential cardiac segmentation was reduced significantly by the use of the SCT scheme.
  • Keywords
    biomedical MRI; cardiology; image segmentation; medical image processing; active contour model; automatic sequential segmentation; endocardial boundary; error propagation; myocardial boundaries; phase contrast MRI data sets; phase contrast magnetic resonance imaging; seed contour tracking; sequential cardiac segmentation;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:20046608
  • Filename
    1358937