DocumentCode
1165688
Title
Recovery Times of Vaccum Interrupters Which have Stationary Anode Spots
Author
Frind, G. ; Carroll, J.J. ; Goody, C.P. ; Tuohy, E.J.
Author_Institution
General Electric Research & Development Center
Issue
4
fYear
1982
fDate
4/1/1982 12:00:00 AM
Firstpage
775
Lastpage
782
Abstract
With rectangular power current waves recovery times of a vacuum interrupter with copper-based button contacts were measured. They were found to increase from 7 , ¿at 250 A to 630 ¿s at 12 kAp, where a stationary anode spot had formed. With a stationary anode spot present recovery time was also approximately proportional to current pulse duration. An attempt was made to explain the long recovery times by evaporation from the highly heated anode after the current had ceased. In addition, some high-speed photographic observations were made on the formation of stationary anode spots.
Keywords
Anodes; Cathodes; Cooling; Current measurement; Electric variables measurement; Electrodes; Interrupters; Motion pictures; Power measurement; Vacuum arcs;
fLanguage
English
Journal_Title
Power Apparatus and Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9510
Type
jour
DOI
10.1109/TPAS.1982.317141
Filename