DocumentCode :
11667
Title :
The effect of surface roughness on corona-generated electromagnetic interference for long-term operating conductors
Author :
Xingming Bian ; Yuanjiu Wang ; Liming Wang ; Zhicheng Guan ; Shuwei Wan ; Lan Chen ; Fangdong Chen ; Xuesong Zhao
Author_Institution :
State Key Lab. of Alternate Electr. Power Syst. with Renewable Energy Sources, North China Electr. Power Univ., Beijing, China
Volume :
22
Issue :
2
fYear :
2015
fDate :
Apr-15
Firstpage :
879
Lastpage :
887
Abstract :
This paper presents a research of the surface roughness effects on corona-generated electromagnetic interference of long-term operating conductors. The detailed surface morphologies and roughness of typical long-term operating conductors were measured and analyzed. The radio noise measurement system based on the corona cage was discussed and the actual radio noise generated by the conductor in the measured cage was obtained, based on the parameters of the corona cage and the measured data. The radio noise tests were carried out under both dry and wet conditions. Under two types of conditions, the corona intensity was higher on the long-term operating conductors contrasted to the new conductors as a result of the anomalistic surfaces of the long-term operating conductors. The rate of decrease of corona inception voltages between the long-term operating conductors and new conductors was discovered to increase with the raise of surface roughness degree Ra in linear relationship. Approximate linear relation was also discovered between the averaged radio noise deviation and Ra. The rate of decrease of corona inception voltages under wet conditions was slightly higher (about 1%) than that under dry conditions. The difference between the radio noise of long-term operating conductors and that of new conductors was larger (1.3 dB) under wet conditions compared to dry conditions.
Keywords :
conductors (electric); corona; radiofrequency interference; surface morphology; surface roughness; AC corona discharge; approximate linear relation; corona cage; corona inception voltage; corona-generated electromagnetic interference; long-term operating conductor; radio noise measurement system; surface morphology; surface roughness effect; Conductors; Corona; Noise; Rough surfaces; Surface discharges; Surface morphology; Surface roughness; AC corona discharge; corona cage; electromagnetic interference; long-term operating conductor; roughness; surface condition;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2015.7076788
Filename :
7076788
Link To Document :
بازگشت