DocumentCode
1167166
Title
AC power line conditioner with switch-clamped topology
Author
Lin, Bor-Ren ; Lee, Yung-Chuan ; Yang, Tsung-Yu
Author_Institution
Dept. of Electr. Eng., Nat. Yunlin Univ. of Sci. & Technol., Taiwan
Volume
39
Issue
5
fYear
2003
fDate
3/6/2003 12:00:00 AM
Firstpage
462
Lastpage
464
Abstract
A new AC line conditioner with high input power factor and clean AC output voltages for isolating the linear or nonlinear loads is introduced. An AC/DC rectifier with switch-clamped topology is adopted to draw the balanced sinusoidal line current from the AC supply system. A three-leg inverter with switch-clamped topology is adopted in the system to provide clean AC output voltages to the critical or sensitive loads. Experimental results show the validity and effectiveness of the proposed control strategy.
Keywords
AC-AC power convertors; AC-DC power convertors; DC-AC power convertors; harmonic distortion; invertors; power conversion harmonics; power factor correction; rectifying circuits; switching convertors; AC power line conditioner; AC/DC rectifier; balanced sinusoidal line current; clean AC output voltages; critical loads; input power factor; sensitive loads; switch-clamped topology; three-leg inverter;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:20030248
Filename
1190014
Link To Document