Title :
Gamma-Ray Attenuation for Characterization of Future Space Launcher Fuels
Author :
Carapelle, A. ; Collette, J.-P.
Author_Institution :
Centre Spatial de Liege, Liege Univ.
Abstract :
Gamma-ray attenuation is used to measure cryogenic mixture density. Parameters are optimized for specific space application. A simple error formula is established. The feasibility of the measurement is demonstrated. The effect of container´s walls is measured. An automatic measurement device is built. A theoretical calculation is made for the geometry of Ariane V launcher
Keywords :
aerospace propulsion; cryogenics; density measurement; gamma-ray detection; measurement errors; space vehicles; Ariane V launcher geometry; automatic measurement device; container wall effects; cryogenic mixture density measurement; error formula; future space launcher fuels; gamma-ray attenuation; space vehicle propulsion; Absorption; Attenuation measurement; Cryogenics; Density measurement; Fuels; Geometry; Hydrogen; Law; Nitrogen; Time measurement; Cryogenics; density measurement; gamma rays; space vehicle propulsion;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2006.880924