DocumentCode
1170456
Title
Thermal Endurance of Enameled Wires Using Twisted Wire Specimens Statistical Analysis of Test Results
Author
Goldenberg, H.
Volume
80
Issue
3
fYear
1961
fDate
4/1/1961 12:00:00 AM
Firstpage
947
Lastpage
953
Abstract
Thermal endurance tests to AIEE No. 571 were performed in six laboratories employing varnished specimens prepared in one laboratory with enameled wire from a single source. The results have been analyzed to test the hypothesis of the departure from linearity of the relationship between the logarithm of life and the inverse of the absolute temperature, with the object of subsequent limited extrapolation. Consideration is given to the variation between the results of different laboratories, and to reducing testing time. Comparison is made with previous AIEE results. Detailed numerical results are given.
Keywords
Coils; Dielectrics and electrical insulation; Extrapolation; H infinity control; Laboratories; Life testing; Performance evaluation; Statistical analysis; Temperature; Wires;
fLanguage
English
Journal_Title
Power Apparatus and Systems, Part III. Transactions of the American Institute of Electrical Engineers
Publisher
ieee
ISSN
0097-2460
Type
jour
DOI
10.1109/AIEEPAS.1961.4501179
Filename
4501179