DocumentCode :
1171549
Title :
A weak magnetic field measurement system using micro-fluxgate sensors and delta-sigma interface
Author :
Kawahito, Shoji ; Cerman, Ales ; Aramaki, Keita ; Tadokoro, Yoshiaki
Author_Institution :
Res. Inst. of Electron., Shizuoka Univ., Hamamatsu, Japan
Volume :
52
Issue :
1
fYear :
2003
fDate :
2/1/2003 12:00:00 AM
Firstpage :
103
Lastpage :
110
Abstract :
This paper presents a weak magnetic field measurement system using micro-fluxgate (FG) sensors and a sensor signal processing technique using the delta-sigma modulation in the negative feedback loop. The feedback of the lowpass filtered bitstream output of a delta-sigma modulator to the magnetic field improves system linearity, hysteresis, and stability. In spite of the fact that the second-order delta-sigma modulator is used, the third-order noise shaping can be obtained in the digital output bit-stream by the use of an integrator in the loop. This improves the SNR of the digital output. The measured noise of the implemented system meets the measured noise of the FG sensing element itself. The weak magnetic field in the range of the Earth´s magnetic field is successfully measured. The nonlinearity error is less than 0.4% in the range of ±100 μT.
Keywords :
fluxgate magnetometers; magnetic field measurement; magnetic hysteresis; microsensors; -100 to 100 muT; SNR; delta-sigma interface; hysteresis; linearity; lowpass filtered bitstream output; micro-fluxgate sensors; negative feedback loop; nonlinearity error; sensor signal processing technique; stability; third-order noise shaping; weak magnetic field measurement system; Delta modulation; Delta-sigma modulation; Magnetic field measurement; Magnetic noise; Magnetic sensors; Negative feedback loops; Noise measurement; Noise shaping; Sensor systems; Signal processing;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2003.809073