DocumentCode :
1173267
Title :
Biological Tissue Complex Permittivity Measured From S_{21} —Error Analysis and Error Reduction by Reference Measurements
Author :
Tofighi, Mohammad-Reza ; Daryoush, Afshin S.
Author_Institution :
Capital Coll., Pennsylvania State Univ., Middletown, PA
Volume :
58
Issue :
7
fYear :
2009
fDate :
7/1/2009 12:00:00 AM
Firstpage :
2316
Lastpage :
2327
Abstract :
Our analysis and measurements of a custom-designed two-port microstrip test fixture for biological tissue characterization at microwave and millimeter-wave frequencies demonstrated that the transmission parameter S 21 would provide a better sensitivity to the complex permittivity change than the reflection coefficient S 11. However, the standard through-reflect-line (TRL) calibration method employed for the extraction of the tissue complex permittivity did not fully remove the coaxial-to-microstrip adaptors\´ induced errors, which were manifested by ripple artifacts on the measured two-port S parameters. A simple deconvolution method was demonstrated wherein these errors were removed by postcalibration correction of the measured S 21 of the tissue under test (TUT) by using water as a reference material. This paper provides a theoretical analysis of this method based on a model presented for postcalibration adaptors. Our detailed analysis shows that the error for S 21 using the deconvolution method linearly depends on the difference between the S 11 of the TUT and the reference material. Measurement and error estimation are also provided for various biological tissues and are consistent with analytical expectations. Our analysis provides support that systematic errors of numerically modeled S 21 utilized for complex permittivity extraction can significantly be reduced by the deconvolution method. On the other hand, the analysis also shows that the S 21 numerical modeling errors and the postcalibration adaptors\´ error terms have a similar impact on the extracted complex permittivity using the standard time-gating technique and are irreducible, unless the deconvolution method is used. Our analysis also identifies water as a better reference sample than methanol for accurate extraction of the complex permittivity of tissues in the range of epsiv- - \´ > 9 and epsiv" > 7 at 30 GHz.
Keywords :
biological tissues; deconvolution; error analysis; permittivity; biological tissue complex permittivity; deconvolution method; error analysis; error reduction; reference measurements; transmission parameter; water; Biological test fixture; biological tissues; complex permittivity measurement; deconvolution method; through–reflect–line (TRL) calibration; time gating;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2009.2013923
Filename :
4787039