DocumentCode :
1173521
Title :
Evaluating the Service Degradation of Large Hydrogen Cooled Generator Rotor Fields
Author :
Nilsson, N.E. ; Mercurio, J.
Author_Institution :
Ohio Edison Company
Issue :
9
fYear :
1983
Firstpage :
2950
Lastpage :
2958
Abstract :
The ideal operation of power plant equipment philosophically entails achieving the maximum useful life without experiencing an in service failure. This paper will describe generally known testing techniques and their application to generator rotor fields. This paper will propose a course of action when degradation begins to be detected. Risks which might be encountered are discussed as are precautionary measures which can be instituted. To support the techniques discussed, a case history will be described in detail.
Keywords :
Circuit testing; Degradation; Hydrogen; Immune system; Impedance; Machinery; Performance evaluation; Power generation; Rotors; Stators;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1983.318136