DocumentCode :
1173964
Title :
An Analysis of Power Detection
Author :
De Cola, Rinaldo
Author_Institution :
Consulting Engineer, Cleveland, Ohio
Volume :
21
Issue :
7
fYear :
1933
fDate :
7/1/1933 12:00:00 AM
Firstpage :
984
Lastpage :
989
Abstract :
The reasons for overloading of detectors as output devices is discussed. It is shown that in grid circuit rectification replacing the grid leak with a high impedance choke extends the overload point considerably. Using a 247 type pentode 800 milliwatts are obtained at the output circuit with seven per cent maximum distortion.
Keywords :
Circuits; Detectors; Fluctuations; Impedance; Inductors; Leak detection; Power engineering and energy; Rectifiers; Resistors; Voltage;
fLanguage :
English
Journal_Title :
Radio Engineers, Proceedings of the Institute of
Publisher :
ieee
ISSN :
0731-5996
Type :
jour
DOI :
10.1109/JRPROC.1933.227835