DocumentCode :
1174886
Title :
The Measurement of Harmonic Power Output of a Radio Transmitter
Author :
Honnell, P.M. ; Ferrell, E.B.
Author_Institution :
Bell Telephone Laboratories, Inc., Deal, New Jersey
Volume :
22
Issue :
10
fYear :
1934
Firstpage :
1181
Lastpage :
1190
Abstract :
A method of determining the harmonic power output of a high-frequency radio transmitter is described. It is a method for measuring the power delivered by the transmitter to the antenna system, as distinguished from the more common method of measuring harmonic field strengths at specified locations. It is essentially a comparison method. The unknown harmonic power, present with the fundamental, is compared by means of a sufficiently selective receiving set with a known comparison power which is supplied in the absence of the fundamental. The method in practice seems to be accurate within about one decibel. It is applicable to the measurement of power other than harmonic power.
Keywords :
Antenna measurements; Calibration; Current measurement; Frequency measurement; Interference; Power measurement; Power supplies; Power system harmonics; Radio transmitters; Transmitting antennas;
fLanguage :
English
Journal_Title :
Radio Engineers, Proceedings of the Institute of
Publisher :
ieee
ISSN :
0731-5996
Type :
jour
DOI :
10.1109/JRPROC.1934.226669
Filename :
1685523
Link To Document :
بازگشت