DocumentCode :
1175597
Title :
Surface Breakdown Characteristics of Rubber Insulating Gloves Exposed Outdoors
Author :
Hammam, M.S.A.A. ; Yoshimura, N. ; Adams, G. ; Fini, A. ; Nowak, H.
Author_Institution :
Clarkson College of Technology
Issue :
3
fYear :
1984
fDate :
3/1/1984 12:00:00 AM
Firstpage :
449
Lastpage :
454
Abstract :
Surface flashover and tracking breakdown tests were carried out on rubber insulating gloves under various relative humidities and fog and rain conditions, and on gloves which have been exposed outdoors for various periods of time. When gloves are exposed outdoors, cracks and recesses form on the glove surfaces. Direct exposure to rain and fog has a noticeable effect on the flashover voltage. With an increase in the period of exposure outdoors, the time to tracking breakdown decreases.
Keywords :
Aging; Electric breakdown; Flashover; Humidity; Insulation life; Protection; Rain; Rubber; Senior members; Testing;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1984.318722
Filename :
4112540