Title :
Magnetic-probe diagnostics for railgun plasma armatures
Author :
Parker, Jerald V.
Author_Institution :
Los Alamos Nat. Lab., NM, USA
fDate :
6/1/1989 12:00:00 AM
Abstract :
The author assesses the strengths and weaknesses of the various magnetic-probe techniques currently in use and provides recommendations for future improvements in magnetic probe diagnostics for plasma-armature railguns. Analytic approximations for the dependence of the probe signal on probe location and railgun geometry are presented. Rail current and armature current probes are compared and contrasted with respect to resolution and accuracy. Further improvements in measurement accuracy are predicted for close-spaced magnetic-probe arrays
Keywords :
electromagnetic launchers; plasma probes; armature current probes; close-spaced magnetic-probe arrays; diagnostics; magnetic-probe techniques; measurement accuracy; probe location; probe signal; railgun geometry; railgun plasma armatures; resolution; Accuracy; Geometry; Magnetic analysis; Plasma diagnostics; Plasma measurements; Probes; Railguns; Rails; Signal analysis; Signal resolution;
Journal_Title :
Plasma Science, IEEE Transactions on