Electroquasistatic Analysis of the Gas Insulated Line for the ITER Neutral Beam Injector
Author :
Bettini, P. ; Specogna, R. ; Trevisan, F.
Author_Institution :
Dip. di Ing. Elettr., Univ. degli Studi di Udine, Udine
Volume :
45
Issue :
3
fYear :
2009
fDate :
3/1/2009 12:00:00 AM
Firstpage :
996
Lastpage :
999
Abstract :
In this paper, we formulate an electroquasistatic problem according to the discrete geometric approach. As an application, the transient behavior of the gas insulated transmission line for the ITER neutral beam injector system is analyzed.
Keywords :
Tokamak devices; fusion reactor ignition; gas insulated transmission lines; geometry; plasma beam injection heating; transients; ITER neutral beam injector system; discrete geometric method; electroquasistatic analysis; gas insulated transmission line; transient behaviour; Cell´s method; FIT; ITER; NBI; discrete geometric approach; electroquasistatics; high voltage applications;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2009.2012538