DocumentCode
1179537
Title
Resolution Accuracy Confidence Limits for Cascaded Induction Resolvers
Author
Rue, A.K. ; Fisk, J.W.
Author_Institution
Infrared Systems and Guidance Heads Laboratory, Hughes Aircraft Company, Culver City, Calif.
Issue
4
fYear
1964
Firstpage
271
Lastpage
277
Abstract
Induction resolvers are commonly used as coordinate converters in many systems in which vector resolution is required. In systems that require several coordinate conversions, the error due to the conversion mechanism may limit the accuracy of the system. Because of the inherent nonlinear nature of coordinate conversion, this error is, in general, difficult to determine. In this paper, a resolver model and a statistical basis for computing the error due to the conversion mechanism are developed. Two example resolver coordinate converters and the confidence limits for their resolution accuracy are presented.
Keywords
Aerospace electronics; Aircraft; Circuits; Damping; Frequency; Navigation; Servomechanisms; Silicon compounds; Torque control; Voltage control;
fLanguage
English
Journal_Title
Aerospace and Navigational Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0096-1957
Type
jour
DOI
10.1109/TANE.1964.4502211
Filename
4502211
Link To Document