DocumentCode
1179601
Title
Grid Temperature as a Limiting Factor in Vacuum Tube Operation
Author
Mouromtseff, I.E. ; Kozanowski, H.N.
Author_Institution
Westinghouse Electric and Manufacturing Company, East Pittsburgh, Pa.
Volume
24
Issue
3
fYear
1936
fDate
3/1/1936 12:00:00 AM
Firstpage
447
Lastpage
454
Abstract
A method for determining the grid dissipation at which primary or thermionic emission from the grid begins has been devised. By means of suitable rectifiers and an alternating-current source, the grid is heated during positive half cycles and the presence of primary emission is determined during negative half cycles. A variation of this method also enables one to measure the grid dissipation limited by primary emissions when the plate is heated. Sample values of grid limits for individual tubes of familiar types are given. The effect of gas on permissible grid dissipation is briefly discussed.
Keywords
Circuits; Electron emission; Electron tubes; High power amplifiers; Manufacturing; Operational amplifiers; Rectifiers; Temperature; Thermionic emission; Voltage;