DocumentCode :
1179774
Title :
Automatic Compensation for Class B Bias and Plate Voltage Regulation
Author :
Rockwell, R.J. ; Platts, G.F.
Author_Institution :
Crosley Radio Corporation, Cincinnati, Ohio
Volume :
24
Issue :
4
fYear :
1936
fDate :
4/1/1936 12:00:00 AM
Firstpage :
553
Lastpage :
558
Abstract :
A method of automatically compensating for the effects of bias and plate-voltage regulation in class B stages is outlined. It obviates the necessity of using heavy current bleeders where rectifier bias supply is used, and is shown to be more desirable than battery bias. A typical installation using low power tubes is described, but the principle may be applied to an installation of any desired power. It is shown further that such a system imposes less severe requirements on the plate supply as regards regulation. The only sacrifice entailed is a slight reduction in peak power output due to reduction in supply voltage on modulation peaks.
Keywords :
Batteries; Broadcasting; Circuits; Helium; Load management; Low voltage; Nonlinear distortion; Rectifiers; Voltage control; Voltage fluctuations;
fLanguage :
English
Journal_Title :
Radio Engineers, Proceedings of the Institute of
Publisher :
ieee
ISSN :
0731-5996
Type :
jour
DOI :
10.1109/JRPROC.1936.226857
Filename :
1686125
Link To Document :
بازگشت