DocumentCode :
1180044
Title :
Aging of cellulose at transformer service temperatures. Part 2. Influence of moisture and temperature on degree of polymerization and formation of furanic compounds in free-breathing systems
Author :
Höhlein, I. ; Kachler, A.J.
Author_Institution :
Siemens Transformer Factory, Nuremberg, Germany
Volume :
21
Issue :
5
fYear :
2005
Firstpage :
20
Lastpage :
24
Abstract :
This paper examines the influence of moisture and temperature on the degree of polymerization (DP) and furanic compounds. At normal service temperatures, the average moisture content in the solid insulation of transformers has a much stronger influence on the development of furanic compounds and degradation of the insulation than temperature itself. The influence of the initial moisture in the solid insulation on aging under normal transformer service temperatures of 75, 85, and 95 °C has been investigated experimentally. Wet transformers have usually higher levels of furans, inferior oil properties, and lower DP values of paper than dry ones under similar service conditions. The development of furan concentration and moisture content are very important aging indicators for the evaluation and life assessment of transformer in service. Further work is necessary to combine these important aging characteristics into a valuable tool for the assessment of a large aging transformer population.
Keywords :
ageing; moisture; paper; polymerisation; power transformer insulation; transformer oil; 75 degC; 85 degC; 95 degC; cellulose aging; degree of polymerization; free-breathing systems; furanic compounds; life assessment; moisture content; solid insulation; transformer service temperatures; Aging; IEC standards; Moisture; Oil insulation; Petroleum; Plastic insulation; Polymers; Power transformer insulation; Solids; Temperature;
fLanguage :
English
Journal_Title :
Electrical Insulation Magazine, IEEE
Publisher :
ieee
ISSN :
0883-7554
Type :
jour
DOI :
10.1109/MEI.2005.1513426
Filename :
1513426
Link To Document :