    Dynamic performance of a synchronous generator-fourth order microcomputer model

  • Author

    Abu-Elnaga, Moneer M. ; Alden, Robert T H

  • Author_Institution
    McMaster Univ., Hamilton, Ont., Canada
  • Volume
    4
  • Issue
    1
  • fYear
    1989
  • fDate
    2/1/1989 12:00:00 AM
  • Firstpage
    264
  • Lastpage
    270
  • Abstract
    A highly interactive computer program is described that enables the student to examine the dynamic performance of a synchronous generator described by a fourth-order model. The facilities provided in this program are intended to improve student understanding of physical system behavior. The program is written in FORTRAN with calls to the ZABLIB library and is implemented on a TI microcomputer that uses the MS-DOS operating system. The algorithms described in this program include eigenvalue tracking and time-response plotting. The different facilities and the associated menus and screens are presented and discussed
  • Keywords
    electric machine analysis computing; synchronous generators; FORTRAN; MS-DOS operating system; TI microcomputer; dynamic performance; eigenvalue tracking; fourth order microcomputer model; interactive computer program; synchronous generator; time-response plotting; Eigenvalues and eigenfunctions; Engineering education; Libraries; Microcomputers; Operating systems; Power engineering and energy; Power engineering computing; Power system modeling; Synchronous generators; Voltage;