DocumentCode :
1181145
Title :
Air Cycle Cooling System for HPOF Cables-Waltz Mill Tests
Author :
Burghardt, R.R. ; Cooper, J.H.
Author_Institution :
Westinghouse Electric Corporation
Issue :
4
fYear :
1985
fDate :
7/1/1985 12:00:00 AM
Firstpage :
761
Lastpage :
767
Abstract :
A prototype air cycle cooling system, designed for forced cooling of HPOF pipe-type cable, was built under an EPRI contract. Its main components are a turbine and compressor operated on a single high speed shaft and a compact cable. oil to air heat exchanger. Air cooling is supplemented by a spray water system. Tests were conducted on the prototype unit at the EPRI Waltz Mill Cable Test Facility to evaluate its performance and operating characteristics. This paper briefly describes this equipment and presents the results of the test program.
Keywords :
Contracts; Cooling; Milling machines; Oil filled cables; Petroleum; Prototypes; Shafts; Spraying; System testing; Turbines;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1985.319071
Filename :
4113151
Link To Document :