• DocumentCode
    1182437
  • Title

    Investigation of Back-to-Back Starting of Pumped Storage Hydraulic Generating Units

  • Author

    Konidaris, D. N.

  • Author_Institution
    Public Power Corporation, Greece
  • Volume
    22
  • Issue
    3
  • fYear
    2002
  • fDate
    3/1/2002 12:00:00 AM
  • Firstpage
    57
  • Lastpage
    57
  • Abstract
    In the present paper the procedure of back-to-back starting of pumped storage hydraulic generating units is investigated and analyzed. The results from simulation as well as from real on-site measurements are presented and compared for a case study of a Greek power station. Main parameters influencing this phenomenon are analyzed and information is given on the physical laws underlying the process. The effects of excitation and the gate valve opening procedure are discussed in particular, along with the torque-speed characteristic of the driving machine. Guidance is developed for the proper selection of the main parameters for a successful start.
  • Keywords
    Aging; Conductors; Degradation; Eddy currents; Hydroelectric power generation; Power cables; Power distribution lines; Power generation; Space technology; Wire; Hydroelectric generators; back-to-back starting; pumped storage power generation; rotating machine thermal factor; starting;
  • fLanguage
    English
  • Journal_Title
    Power Engineering Review, IEEE
  • Publisher
    ieee
  • ISSN
    0272-1724
  • Type

    jour

  • DOI
    10.1109/MPER.2002.4312057
  • Filename
    4312057