• DocumentCode
    1182577
  • Title

    Balance of System Costs for a 5 MW Photovoltaic Generating System

  • Author

    Shushnar, G.J. ; Caldwell, J.H., Jr. ; Reinoehl, R.F. ; Wilson, J.H.

  • Author_Institution
    ARCO Solar, Inc.
  • Issue
    8
  • fYear
    1985
  • Firstpage
    2006
  • Lastpage
    2011
  • Abstract
    A cost study was conducted of a 12.2 million kWh/year (5 MW) photo- voltaic power plant of various configurations using actual data and experience from ARCO Solar´s large-scale PV´ projects in California. System costs were divided into PV costs and all BOS cost elements, which were grouped into area-related costs (inversely dependent on PV efficiency), power-related costs, and fixed costs. PV and area-related BOS costs make up 75% to 85% of total cost in all cases studied. Study results indicate the high sensitivity of BOS costs to PV efficiency, system configuration design, and BOS equipment design, and identify efficiency and configuration as the most effective avenues for BOS and system cost reduction.
  • Keywords
    Costs; Inverters; Large-scale systems; Meeting planning; Performance analysis; Photovoltaic systems; Power & Energy Society; Power generation; Solar power generation; Terrorism;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1985.318774
  • Filename
    4113340