• DocumentCode
    1183940
  • Title

    An Adaptive Distance Relay and Its Performance Comparison with a Fixed Data Window Distance Relay

  • Author

    Sidhu, Tarlochan S. ; Ghotra, D. S. ; Sachdev, M. S.

  • Author_Institution
    University of Saskatchewan
  • Volume
    22
  • Issue
    5
  • fYear
    2002
  • fDate
    5/1/2002 12:00:00 AM
  • Firstpage
    69
  • Lastpage
    69
  • Abstract
    This paper describes the design, implementation, and testing of an adaptive distance relay. The relay uses a fault detector to determine the inception of a fault and then, uses data windows of appropriate length for estimating phasors and seen impedances. Hardware and software of the proposed adaptive relay are described in the paper. The relay was tested using a model power system and a real-time playback simulator. Performance of the relay was compared with a fixed data window distance relay. Some results are reported in the paper. The results indicate that the adaptive distance relay provides faster tripping in comparison to the fixed data window distance relay.
  • Keywords
    Electrical fault detection; Hardware; Impedance; Power system faults; Power system modeling; Power system relaying; Power system simulation; Protective relaying; Real time systems; System testing; Distance relays; adaptive relaying; line protection; microprocessor-based relays;
  • fLanguage
    English
  • Journal_Title
    Power Engineering Review, IEEE
  • Publisher
    ieee
  • ISSN
    0272-1724
  • Type

    jour

  • DOI
    10.1109/MPER.2002.4312219
  • Filename