• DocumentCode
    1184016
  • Title

    A Study on the Impact of Low-Amplitude Oscillatory Switching Transients on Grid Connected EHV Transformer Windings in a Longitudinal Power Supply System

  • Author

    De, Abhinandan ; Debnath, Dilip ; Chakrabarti, Abhijit

  • Author_Institution
    Dept. of Electr. Eng., Bengal Eng. & Sci. Univ., Howrah
  • Volume
    24
  • Issue
    2
  • fYear
    2009
  • fDate
    4/1/2009 12:00:00 AM
  • Firstpage
    679
  • Lastpage
    686
  • Abstract
    Switching events in inter connected power systems have significant effects on EHV transformers. Standard high-voltage lightning and switching impulse tests are performed on EHV transformers during manufacture, to ascertain breakdown strength of insulation used. But, during their service, transformers encounter numerous voltage transients of complex and varying wave shapes which do not necessarily resemble these standard surge type voltages. Transformers are complex assembly of coils around magnetic core having inductances and capacitances and therefore, exhibit unique frequency response characteristics with several natural resonate frequencies. Oscillatory overvoltages originating in power systems due to switching, faults and other phenomena often traverse through transformers and can excite one or more of the winding´s natural resonate frequencies resulting severe internal voltage amplification and damage to insulation even when the terminal excitation voltages have relatively low amplitude. Adequate consideration must therefore be given to such low amplitude oscillatory transient voltages while designing insulation for grid connected EHV transformers. In this paper, the authors have analyzed the voltage stresses developed in the windings of a 400/220/33-kV grid connected transformer operating in the Eastern Regional Power Grid of India, when natural frequencies of the transformer winding are triggered by oscillatory switching transients. The developed voltage stresses have been compared with those under standard laboratory dielectric tests including newly incorporated fast front-long tailed switching surges.
  • Keywords
    overvoltage; power grids; power transformer protection; switching transients; transformer windings; breakdown strength; grid connected EHV transformer windings; longitudinal power supply system; low-amplitude oscillatory switching transients; oscillatory overvoltages; EMTP; overvoltage; resonance; switching transients; transformer;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.2008.2008417
  • Filename