DocumentCode :
1184666
Title :
On the use of Directional Microphones for Turbine-Generator Sound Level Measurements
Author :
Hribar, A.E. ; Niskode, P.M.
Author_Institution :
Acoustics and Noise Control Research Westinghouse Electric Corporation
Issue :
3
fYear :
1979
fDate :
5/1/1979 12:00:00 AM
Firstpage :
1104
Lastpage :
1108
Abstract :
Accurate measurements of the noise levels produced by turbine-generators are difficult to obtain because of the highly reverberant character of the turbine halls. The use of directional microphones to discriminate against the reverberant sound and improve the measurement accuracy has been investigated. The results show that effective signal-to-background noise gains of 3 to 7 dB can be achieved. The capabilities, limitations and areas which need additional work are specified.
Keywords :
Acoustic measurements; Acoustic noise; Cardiology; Electric variables measurement; Level measurement; Microphones; Noise level; Noise measurement; Power generation; Turbines;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1979.319280
Filename :
4113580
Link To Document :
بازگشت