• DocumentCode
    1184815
  • Title

    Power Plant Fan Noise Data

  • Author

    Graham, J. Barrie

  • Author_Institution
    Director of Research Buffalo Forge Company
  • Issue
    4
  • fYear
    1979
  • fDate
    7/1/1979 12:00:00 AM
  • Firstpage
    1174
  • Lastpage
    1177
  • Abstract
    Power plant fans have been identified as a major contributor to the total plant noise spectrum. In common with all large industrial fans, power plant fans transfer energy from the shaft to energy in the air in the form of flow rate and pressure. These fans require from 2000 hp to 9000 hp and although only a fraction of one percent of this energy appears as sound energy, the resulting noise levels are very high. There is no practical way that this transfer of energy can be done without creating high noise levels. In order to forumlate an effective program of noise reduction for these large fans it is necessary to understand some of the background data on fan design and operation.
  • Keywords
    Acoustic noise; Acoustical engineering; Blades; Construction industry; Design engineering; Fans; Noise level; Noise reduction; Power generation; Shafts;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1979.319313
  • Filename
    4113599