DocumentCode :
1184815
Title :
Power Plant Fan Noise Data
Author :
Graham, J. Barrie
Author_Institution :
Director of Research Buffalo Forge Company
Issue :
4
fYear :
1979
fDate :
7/1/1979 12:00:00 AM
Firstpage :
1174
Lastpage :
1177
Abstract :
Power plant fans have been identified as a major contributor to the total plant noise spectrum. In common with all large industrial fans, power plant fans transfer energy from the shaft to energy in the air in the form of flow rate and pressure. These fans require from 2000 hp to 9000 hp and although only a fraction of one percent of this energy appears as sound energy, the resulting noise levels are very high. There is no practical way that this transfer of energy can be done without creating high noise levels. In order to forumlate an effective program of noise reduction for these large fans it is necessary to understand some of the background data on fan design and operation.
Keywords :
Acoustic noise; Acoustical engineering; Blades; Construction industry; Design engineering; Fans; Noise level; Noise reduction; Power generation; Shafts;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1979.319313
Filename :
4113599
Link To Document :
بازگشت