Breakdown Probability Distribution and Equi-Probabilistic V-T Characteristics of Transformer Oil
Author :
Ikeda, M. ; Menju, S.
Author_Institution :
Tokyo Shibaura Electric Co., Ltd.
Issue :
4
fYear :
1979
fDate :
7/1/1979 12:00:00 AM
Firstpage :
1430
Lastpage :
1438
Abstract :
Breakdown probability distributions of transformer oil are investigated by applying repeatedly ac voltages with various durations. It is suggested from the test results that the Weibull distribution defined by the shape parameter of ca. 8 fits the breakdown probability distribution of oil. The breakdown probability distributions of oil do not seem to depend on the stressing time.
Keywords :
Breakdown voltage; Dielectrics and electrical insulation; Electric breakdown; Frequency; Insulation testing; Oil insulation; Petroleum; Power transformer insulation; Power transformers; Probability distribution;