Title :
Mitigation of Buried Pipeline Voltages Due to 60 Hz AC Inductive Coupling Part II --Pipeline Grounding Methods
Author :
Dabkowski, John ; Taflove, Allen
Author_Institution :
IIT Research Institute
Abstract :
This paper presents useful mitigation techniques for the reduction of voltages induced on gas transmission pipelines by 60 Hz ac power transmission lines sharing a joint right-of-way. Part II describes how pipeline grounding methods can be implemented to reduce pipeline voltage peaks after installation of the utilities on the joint right-of-way. The use of properly -designed grounding systems permits the maximum mitigation of pipeline voltages at minimum cost.
Keywords :
Anodes; Conductors; Electric shock; Electrostatics; Equivalent circuits; Grounding; Hazards; Impedance; Pipelines; Voltage;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1979.319499