Abstract
A continuous-conduction-mode boost converter with reduced reverse-recovery loss is proposed. By utilising the auxiliary winding of the boost inductor, two additional rectifiers and an auxiliary inductor, the current decrease rates (di/dt) of the boost output rectifier and two additional rectifiers are slowed down to reduce the reverse-recovery loss. Experimental results for a 600 W power factor correction AC/DC boost converter at a constant switching frequency of 100 kHz are obtained to show the performance of the proposed converter. It is shown that a significant efficiency improvement is achieved.
Keywords
AC-DC power convertors; power factor correction; rectifiers; switching convertors; 100 kHz; 600 W; AC/DC boost converter; auxiliary inductor; auxiliary winding; boost inductor; constant switching frequency; continuous-conduction-mode; power factor correction; rectifier; reverse-recovery loss reduction;