• DocumentCode
    1187436
  • Title

    Improve Turbine-Generator Protection for Increased Plant Reliability

  • Author

    Baldwin, M.S. ; Elmore, W.A. ; Bonk, J.J.

  • Author_Institution
    Westinghouse Electric Corp.
  • Issue
    3
  • fYear
    1980
  • fDate
    5/1/1980 12:00:00 AM
  • Firstpage
    982
  • Lastpage
    989
  • Abstract
    Recent operating experience has prompted a reappraisal of generating unit protection to insure that damage from all potential hazards will be minimized. Eight aspects of unit protection for which new or modified protection is desirable are discussed. Conventional protective relay systems should be supplemented with monitoring systems to detect incipient fault conditions.
  • Keywords
    Frequency synchronization; Hazards; Power generation; Power system protection; Protective relaying; Relays; Rotors; Shafts; Stators; Voltage;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1980.319728
  • Filename
    4113894